Sign In | Join Free | My chinacsw.com
China Chengdu Mechan Electronic Technology Co., Ltd logo
Chengdu Mechan Electronic Technology Co., Ltd
Chengdu Mechan Electronic Technology Co., Ltd Manufacture and leader of bipolar Plasma Surgery System (generator and instruments) for ENT / Orthopedic / Urology / Ophthalmology.
Verified Supplier

6 Years

Home > ENT Probe >

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System

Chengdu Mechan Electronic Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System

  • 1
  • 2
  • 3

Brand Name : MECHAN

Model Number : PLA401

Certification : CE, ISO13485

Place of Origin : CHINA

MOQ : Negotiation

Price : Negotiation

Payment Terms : T/T, L/C

Supply Ability : 100000 sets per year

Packaging Details : carton

Ablation : Adjustable from 1 to 10

Coagulation : Adjustable from 1 to 10

Application : Tonsillectomy, Adenoidectomy, CAUP, UPPP

Advantage : Minimally Invasive, Low Temperature

Warranty : 24 months after sterilization

Shaft Length : 120mm

Usage : Ablation, Cutting, Resection, Hemostasis

Feature : Disposable

Contact Now

Tonsillectomy Plasma Wand ENT Probe For Snoring Treatment System

Product Introduction

PLA401 is design specially for Tonsillectomy, Adenoidectomy, CAUP, UPPP treatment. It is suitable for the length of the blade required for tonsil and adenoid surgery. During adenoidectomy, it is easier to access the hyperplasia tissue in the posterior nostril, and the blade is easier to bend. It has the function of cutting, ablation, hemostasis and coagulation. It is connect with PLA-700 ENT plasma surgery system to perform the operation.

Product Tip Picture

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System

Product Application

  • Repeated acute attacks of chronic tonsillitis;
  • A history of abscesses around the tonsils;
  • Excessive hypertrophy of the tonsils, preventing swallowing or breathing, or affecting eustachian tube function;
  • simple III degree hypertrophy or near III degree hypertrophy tonsils;
  • Patients with rheumatic fever, nephritis, arthritis, and rheumatic heart disease who have suspected tonsils as the lesion;
  • Benign tonsil tumors.

Product Advanatages

  • Safety: Compared with traditional surgical methods (such as: electric knife, laser), the current does not flow through the human body, the working surface temperature is only 40 ° C to 70 ° C, and the surrounding tissue is less thermally damaged. When used in the recommended energy range, the cutting and ablation depth is controlled to ≤50μm.
  • Minimally Invasive: Compared with traditional surgical methods (such as electric knife, laser), it has less heat, reduces tissue thermal damage, reduces wound healing time, reduces wound bleeding and scar formation
  • High Efficiency: Compared with traditional surgical methods (such as: electric knife, laser), the patient's pain during surgery is significantly reduced, and the incidence of postoperative inflammation is significantly reduced. During the surgery, the doctor stops bleeding while cutting, and does not need other hemostasis tools.

System Set Up

Description Remark
Manufacturer Logo MECHEN Brand.
Working Frequency 50Hz
Receptacle of Footswitch Connects with Footswitch which determines ablation or coagulation mode.
Receptacle of Treatment Handle Connects with the treatment accessories.
Power Switch System start power button. “O” means power off; “I” means power on.
ABLATION mode Selector Select ABLATION mode 1 or 2 Output waveform.
Indicator of Treatment Probe Connection LED turns on green when the probe cable is connected and turns on red when it is not connected.
Indicator of Footswitch Connection LED turns on green when the footswitch cable is connected and turns on Red when it is not connected.
ABLATION Power Setting Display

Shows the preset ABLATION output value in two digits.

“01” with Min. power output, and “10” with the highest output.

Ablation Output Power Up/Down Button The number displayed indicates the ablation nominal power, in watts, which will be delivered to the patient when the mode is activated. Only available for changing in ready mode.

Anesthesia

General anesthesia

Cutting Principle

Relying on the mechanical kinetic energy of the plasma in the electric field, it hits the molecular bonds (40-70 ° C) of the target tissue to lyse and ablate. The thermal damage depth is less than 0.5mm, and the trauma to normal adjacent tissues is small.

Treatment Diseases

Tonsillectomy, Adenoidectomy, CAUP, UPPP

Storage Condition

Electrodes shall be stored in environment of humidity less than 80%. no corrosive gas, well vented room. Taking complete protection to electrodes.

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System


Product Tags:

ent surgical instruments

      

portable plasma wand

      
Quality PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System for sale

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chengdu Mechan Electronic Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0